MASTERTUBE Jaune Kit d'extension - 10 m
prêt à l'emploi, composé de :
10 m de tuyau d'injection MASTERTUBE, matériel de pose inclus

numéro d'article 030055

Système de tuyau d’injection MASTERTUBE

Test de résistance à l'eau sous pression Qualité testée

High demands are placed on the technology used to seal concrete construction joints.
The MASTERTUBE injection hose ensures reliable and permanent sealing of horizontal and
vertical concrete construction joints against pressurised and non-pressurised water.

bag contains:

10 m MASTERTUBE YELLOW injection hose
2 fastening packers
100 plastic fastening clips Type B
2 hose connectors

Ajouter à la notice

Aperçu des informations les plus importantes

numéro d'article:
030055
groupe d'articles:
301 - Injektionsschlauch Verlegeset
GTIN:
4251689514210
Conditionnement :
Set
unite de quantité de vent:
1 Set
Matériau:

Tuyau PVC

scope of delivery:

10 m MASTERTUBE YELLOW injection hose
2 fastening packers
100 plastic fastening clips Type B
2 hose connectors

stockage:
Conserver dans l'emballage d'origine intact et non ouvert, au sec et à l'abri de la lumière directe du soleil.
mis au rebut:
Peut être éliminé dans des décharges d'ordures ménagères en respectant les dispositions locales en matière d'élimination des déchets.

Installation of injection hose

   

The injection hose MASTERTUBE “YELLOW” serves as internal waterproofing of construction joints.
-The length of the hose sections must not exceed 15 m. Shorter injection hose sections facilitate later injection.
- The injection hose is installed in the centre of the construction joint or – in case of constructional elements with a thickness of > 60 cm – at a distance of 15 cm from the water-remote side of the structure.
- Ensure a distance of 8 cm from the edge on all sides.

 

 

 

 


The concrete surface which the MASTERTUBE “YELLOW” is to be installed on must be as follows:
- clean and free from cavities
- free from loose particles and cement slurry
- free from release agents or other components that are separating or interfering with the adhesive bond
- free from ice and standing water

MASTERTUBE “YELLOW” is supplied as rolls of 100 m length.
 
Cut the hose with a suitable cutting tool. Prior to cutting, mask the cutting section with 2 – 3 wraps of filament tape, which prevents the hose from tearing in longitudinal direction.

Fastening packers are screwed into the ends of the injection hose sections up to the thread end and fixed to the formwork surface. The position of the fastening packer should ensure permanent accessability (floor structure and Technical Building Equipment must be taken into consideration). The fastening packers have closure plugs in 2 different colours. These are used for marking of the pairs used for the individual hose sections.
 
Successive injection hose sections must overlap by at least 10 cm to ensure continuous injection of the joint. The distance between parallel injection hoses must be min. 5 cm. Otherwise during injection of one hose section, the adjacent hose section might accidentally be filled as well.
 
If the distance of 5 cm cannot be provided in any subsection, this part of one of the hoses needs to be completely wrapped with filament tape in order to prevent accidental injection.

Alternatively, you may use injection end pieces instead of the fastening packers. These are 50 cm long unslit hoses with fabric sheath. By use of hose connectors the injection end pieces are screwed into the ends of the injection hose sections up to the thread. Fixing to the formwork surface is done by use of storage boxes, which the injections end pieces are led into and stored until later injection. The connection point between injection hose and injection end piece must be surrounded on all sides by at least 10 cm of concrete.
 
The position of the storage box should ensure permanent accessability (floor structure and Technical Building Equipment must be taken into consideration). The injection end pieces are available in 2 different colours. These are used for marking of the pairs used for the individual hose sections.
 
Successive injection hose sections must overlap by at least 10 cm to ensure continuous injection of the joint. The distance between parallel injection hoses must be min. 5 cm. Otherwise during injection of one hose section, the adjacent hose section might accidentally be filled as well.
 
If the distance of 5 cm cannot be provided in any subsection, this part of one of the hoses needs to be completely wrapped with filament tape in order to prevent accidental injection

MASTERTUBE “YELLOW” must be fixed in such a way that it cannot shift neither before nor during concreting.  It can be fastened by using metal clips or plastic fastening clips. The distance between either type of clips must not be more than 15cm in longitudinal direction. On very uneven surfaces and at each change of direction, the distance should be halved.

Changes of direction must be carried out with a sufficient bending radius in order to avoid damage to the hose or an obstruction of the overall injection.
 
The radius must be minimum 5 cm.

When changing between horizontal and vertical installation direction, the injection hose must be routed right into the corner of the joint and routed upwards via a loop. The minimum radius as well as the concrete cover need to be observed.

Injection

Injection of MASTERTUBE “YELLOW” is possible once the concrete has cured, 28 days after concreting at the earliest.
 
During injection the DBV code of practice: “Injection hose systems and swellable linings for construction joints” must be observed.

Status: 23.03.2022


accessoires

accessoires appropriés

PROTECT Résine polyuréthane

polyuréthane gonflante pour l'injection de tuyaux et de fissures faible viscosité et étanchéité élastique durable, long temp...

Produits similaires

Vous trouvez ici des produits similaires.

MASTERTUBE Kit de pose

Les techniques d'étanchéité sont soumises à des exigences très élevées lors de l'étanchement de joints de reprise de bét...

Test de résistance à l'eau sous pression Qualité testée

Contactez nous

We are happy to answer your questions

S'il vous plâit mentionner le nom
please_enter_company
please_enter_city
S'il vous plâit mentionner la adress e-mail
S'il vous plâit mentionner l'objet
S'il vous plâit mentionner le message

Please fill the following captcha to reduce spam.

Veuillez saisir le captcha.

En manque de votre consentement nous ne pouvons pas accepter votre demande de contact