til vandtæt limning under tryk
artikelnummer 040100
Løsningsmiddelfri betonlim baseret på epoxyharpiks
.PROTECT BK er en opløsningsmiddelfri betonlim til vanduigennemtrængelig limning - FC-plugs i FC-vægtykkelser - og til force-fit limning af betonelementer.
Tilføj til meddelelseslisteDe vigtigste oplysninger på et øjeblik
Epoxidharz
.pastaagtig
Tæthed: ca. 1,90 g/cm³
ca. 1,9 kg/m²/mm lagtykkelse
.+ 10 °C up to + 30 °C
Termperature of element minimum + 3 °C over dew point
Forarbejdningstid (ved 50 % relativ luftfugtighed)
20 - 30 minutter (30 °C)
40 - 60 minutter (20 °C)
90 - 120 minutter ( 10 °C )
Hærdning ( fuld mekanisk belastningskapacitet )
( ved 50 % rel. LF )
3 dage ( 30 °C )
. UB 5.1/13-568
.
7 bar (70 m vandsøjle)
.1 kg kompositdåse
.Komponent A 0,5 kg
.
Komponent B 0,5 kg
1 : 1 (efter vægt)
.Beton, vandtæt beton
.
Minimumsalder 18 dage
Tør, skridsikker og støvfri
.Fri for adskillende stoffer som fedt, olie osv.
Søvand og spildevand
.
alkalier
.
Fortyndede syrer
Mineralske olier
Smøremidler og brændstoffer
Forskellige opløsningsmidler
Yderligere modstandsdygtighed på forespørgsel eller via
vores modstandsliste
ca. 75 - 80 N/mm² (forudsætter 100 % befugtning)
.ca. 30 N/mm² (forudsætning 100% befugtning)
.bedst før 12 måneder efter produktion
.
Processing/ Mixing:
Allow the hardener component ( component B ) to flow completely into the master component (component A ). Mix intensively with a slowly rotating stirrer (recommendation: double stirrer with counter-rotating stirrer shafts).
Repot into another receptacle and mix thoroughly again.
The compound must be homogeneous, streak-free before application.
Sealing of fibre cement distance tubes with fibre cement plugs:
After cleaning the inside of the fibre cement distance tubes and removing the loose material, the fibre cement plug is dipped into the PROTECT BK and inserted into the distance tube.
The quantity of PROTECT BK on the plug must be sufficient to ensure that the fibre cement plug is fully glued to the inside of the distance tube over its full length.
Depending on the requirements of the construction site, several fibre cement plugs may have to be installed.
Bonding of concrete components:
Depending on the application, PROTECT BK is evenly applied to the components to be bonded using a spatula, smoothing trowel, toothed trowel or similar.
Make sure that the entire surface is bonded without voids.
Immediately after applying the adhesive, the surfaces to be bonded are pressed together and weighted if necessary. For vertical or overhead bonding, the components must be fixed for at least 12 hours,
depending on temperature and layer thickness.
PROTECT BK can be applied in layer thicknesses of 1 - 20 mm.
Please note:
The relative humidity must not exceed 80 %.
Ensure good ventilation after application and during hardening.
Depending on the substance, concentration and duration of exposure, exposure to chemicals can lead to colour changes on the surface which, however, do not affect functionality.
When exposed to UV rays, epoxy resins generally show a certain colour change and chalking.
Status: 23.03.2022