Crack-inducing prof, for in-situ concrete walls
article number 070279
MASTER Joint sheet metal SFG/ SFE/ FE and SRF
The SRF 125 Multi profiles consist of a coated metal waterstop, perforated retaining rails attached on both sides and additional retaining brackets. Depending on requirements, fastening is carried out via the retaining rails or the hinged, perforated retaining brackets.
Add to notice listThe most important information at a glance
St 37, galvanized
special coating: polymer resin fabric-reinforced
3,0 m
160 mm
2,5 m
365 mm
Test report PB 5.1/14-425-2
MFPA Leipzig
Utility class A for the wear classes 1 and
2 in accordance with the WU guideline
yes
yes
No
original packaging in a dry place out of direct sunlight.
Installation cavity walls
The cavity wall element is positioned with VB joint sheet metal acting as the foundation/wall waterproofing element.
The SRF profile is set vertically and overlapped with the joint sheet metal (overlap ≥ 5 cm).
The adjustable mounting brackets are adjusted to fix them on the face of the cavity wall.
The wall formwork is drilled in order to fix the mounting bracket.
The mounting bracket is fixed with a drive-in plug.
(No nail plugs included we recommend nail-plug 5 x 40 mm)
The overlapping area on the floor/wall joint sheet metal is secured with two fixing clips.
Installation of the SRF profile is complete; the next cavity wall element can be placed.
Installation in-situ concrete
The in-situ concrete element is positioned with VB joint sheet metal acting as the foundation/wall waterproofing element.
The SFG profile is set vertically and overlapped with the joint sheet metal (overlap ≥ 5 cm).
Use the foldable, perforated retaining plates to fix the SRF profile to the reinforcement.
The overlapping area on the floor/wall joint sheet metal is secured with two fixing clips.
Installation of the SRF profile is complete; the next in-situ concrete wall element can be placed.
Status: 23.03.2022
Contact us