VB joint sheet metal JGS strips of 2.40 m
fully coated on both sides

article number 070475

Joint sheet metal VB JGS

Water pressure test Slurry/liquid manure/silage effluent ressistance

Both sides fully coated joint sheet metal

Add to notice list

The most important information at a glance

article number:
070475
article group:
220 - Dichtblech VB JGS
GTIN:
4251689511066
customs tariff number:
73269098
packing unit:
crate
sales quantity unit:
120 m
material:

St 37, galvanized
High resistant coating with special primer, fabric-reinforced

colour:
black
approval:

AbZ / ABG: Z-74.101-209

length of joint sheet metal:

2,4 m

height of joint sheet metal:

160 mm

thickness of joint sheet metal:

approx. 0,6 mm

thickness of special coating:

approx. 0,15 mm

total thickness:

approx. 0,9 mm

packaging:

wooden crate (255 x 30 x 25 cm)
50 strips
55 fixing clips

150 mounting brackets in a separate fabric bag

12 crates per pallet

UV weathering:

Joint sheet metal which has been installed during the first construction stage already must not be exposed to free UV weathering for more than 4 weeks until completely cast in concrete. If construction is interrupted for a prolonged period, the joint sheet metal must be especially protected against UV radiation (dark foils etc.) in order to preserve usability.

thermal scope of application:
- 20°C to + 90°C
storage:
Store in undamaged and unopened
original packaging in a dry place out of direct sunlight.
disposal:
Can be disposed of at municipal waste landfill sites, taking into account the local waste disposal regulations.

Remove the bottom half of the parted protective foil from the special coating.


Place the VB JGS joint sheet metal in the centre of the rising wall on top of the upper reinforcement layer.
Push the mounting brackets with a maximum distance of 70 cm over the sheet metal and fix them to the upper reinforcement layer with binding wire.
The embedment depth in the concrete must be at least 35 mm and must not be more than half the height of the sheet metal.


The VB JGS joint sheet metal  must overlap by at least 6 cm in the area of the joint, in the straight sections and also in the corner area.


To do so, the upper protective foil must be turned back in the area subsequently to be joined.


Overlap the VB JGS joint sheet metal by at least 6 cm and press the two ends firmly together.
The joint must be glued over its full height and entire surface to prevent subsequent water permeation.
There must be no contamination on the adhesive surfaces that could interfere with bonding.


Secure the joint with one of the fixing clips provided and fold the protective foil back onto the special coating.


Prepared joints in the straight sections as well as the corner area.

Once the foundation slab has been concreted, and before the wall formwork is closed, the remaining protective foil must be removed.
The concreting of the wall base and corresponding preparations must be carried out in accordance with the established technical standards.


Special requirements for installation and documentation:

- Processing certificate: The processor confirms to have been informed or instructed regarding the processing instructions, restrictions and changes.

- Acceptance certificate: The processing company and an expert confirm that the VB JGS joint sheet metal has been installed in accordance with the regulations.

- Documentation: There is a documentation obligation regarding the batch number of the installed sealing sheets. This can be taken from the label or the delivery bill.

Status: 23.03.2022


Installation in precast wall

Download DWG

Download PDF

Installation in in-situ concrete

Download DWG

Download PDF

corner and overlap situation

Download DWG

Download PDF

Contact us

We are happy to answer your questions

Please enter name
please_enter_company
please_enter_city
Please enter email
Please enter subject
Please enter message

Please fill the following captcha to reduce spam.

Please enter captcha.

We are not allowed to get in touch if you do not agree with our data privacy statement.