VB joint sheet metal JGS, roll - F
fully coated on both sides with fixing angle

article number 070477

Joint sheet metal VB JGS

Water pressure test Slurry/liquid manure/silage effluent ressistance

Both sides fully coated with high resistant special coating
with fixing feet

Add to notice list

The most important information at a glance

article number:
070477
article group:
220 - Dichtblech VB JGS
GTIN:
4251689511295
customs tariff number:
73269098
packing unit:
Roll
sales quantity unit:
20 m
material:

St 37, galvanized
High resistant coating with special primer, fabric-reinforced

colour:
black
approval:

AbZ / ABG: Z-74.101-209

length of joint sheet metal:

20,00 m

height of joint sheet metal:

160 mm

thickness of joint sheet metal:

approx. 0,6 mm

thickness of special coating:

approx. 0,15 mm

total thickness:

approx. 0,9 mm

packaging:

carton (40 x 40 x 20 cm)
 1 roll
 2 fixing clips

thermal scope of application:
- 20°C to + 90°C
storage:
Store in undamaged and unopened
original packaging in a dry place out of direct sunlight.
disposal:
Can be disposed of at municipal waste landfill sites, taking into account the local waste disposal regulations.

Packaging
1 Role with 20 m
2 fixing clips


Remove the bottom half of the parted protective foil from the special coating.


Place the Joint Sheet Metal VB JGS Role-F on the top reinforcement in the center of the rising wall. Use binding wire to tie the fastening foot to the reinforced layer. The emedment depth in the concrete must be at least 35 mm and must not exceed half of the sheet height (8 cm).

 


By bending and crimping a festenig foot to the opposite side (approx. every 50 cm) the position of the sheet can be addtionally stabilized.


In the corner area, the sheet is bent according to the course of the corner. It is advisable here to bend over a "sharp" edge.


At transition joints, the Joint Sheet Metal VB JGS Role-F must be overlapped by at least 6cm. For this purpose, the protective film is folded badk along the length of the overlap.


The overlapping surfaces are pressed together over the entire surface and secured with one of the supplied fixing clips. Ther must be no dirt on the adhesie surfaces that could impair the bonding.


The Joint Sheet Metal VB JGS Role-F must form a self-contained, defect-free circuit. The upper half of the protective film must remain on the special coating until the latest possible time. The concreting of the wall base and the corresponding preparations for this must be carried out in accordance with the recognized technical regulations.


Special requirements for installation and documentation:

- Processing certificate: The processor confirms to have been informed or instructed regarding the processing instructions, restrictions and changes.

- Acceptance certificate: The processing company and an expert confirm that the Joint Sheet Metal VB JGS Role-F has been installed in accordance with the regulations.

- Documentation: There is a documentation obligation regarding the batch number of the installed sealing sheets. This can be taken from the label or the delivery bill.

Status: 23.03.2022


installation in in-situ concrete

Download DWG

Download PDF

corner and overlap situation

Download DWG

Download PDF

Contact us

We are happy to answer your questions

Please enter name
please_enter_company
please_enter_city
Please enter email
Please enter subject
Please enter message

Please fill the following captcha to reduce spam.

Please enter captcha.

We are not allowed to get in touch if you do not agree with our data privacy statement.