RONDO seinakinnitus ROPRO 630 tüüp Protect
Kinnitusvahemik Ø 625 - 640 mm

Artikli number 091254

Tihenduskaelus RONDO Protect

vastupidavuse test Veesurve katse Radontight
Vee survestamise test
  • Maksimaalne rõhu test kuni 100 m veesamba
Kindlus
  • Loomade väljaheited
  • Siirup
  • Väävelhappe lahustamine
  • Metaanigaas
Lisada märkuste loetellu

Kõige olulisem teave lühidalt

Artikli number:
091254
Artikligrupp:
409 - Rondo Typ Protect
GTIN:
4251689521836
tollitariifi number:
40169300
pakkimisüksus:
pc
müügikoguse ühik:
1 Stk
materjal:

Modifitseeritud TPE

värv:
mädanik
tihedus:
ca. 1,17 kg/dm³
Tihedus:

ca. 1,17 kg/dm³

Kõvadus:

50 ± 5 Shore A

Rebenemiskindlus:

ca. 6,5 N/mm²

Pikenemine murdumisel:

ca. 380%

Sisaldab aineid, mis on loetletud SVHC loetelus või mille osakaal on ≥0,1%.:

Ei

Toode vastab REACH-määrusele:

ja

termiline rakendusala:
ca. -30° C kuni 70° C
veekindlus:
10 baari ( 100 m veesammas)
ladustamine:
Hoida kuivas kohas, eemal otsesest päikesevalgusest.
kõrvaldamine:
Saab kõrvaldada kodumajapidamistes vastavalt kohalikele jäätmekäitlusnormidele.

The RONDO Protect sealing collar is supplied ready-to-install with two stainless steel clamping straps for fixing.

Choose the correct size of RONDO Protect sealing collar corresponding to the outer diameterof the medium pipe to be waterproofed.


Soiled pipe walls must be cleaned prior to installing the RONDO Protect sealing collar.
Soaking in warm water (approx. 10 minutes) makes the sealing collar even easier to install, espacially at low temperatures.
The RONDO Protect sealing collar is pulled on from the spigot end before the pipe is installed.


The RONDO Protect sealing collar should be mounted centrally on the wall/floor plate.
The minimum concrete cover of 5 cm must not be undercut.
The distance to the surrounding reinforcement or other components must be at least 3 cm.


Apply lubricant to the clamping range of the strap, then tighten the clamping straps sufficiently using a screwdriver to prevent the RONDO Protect sealing collar from shifting.

During concreting, ensure thorough compacting around the RONDO Protect sealing collar in order to prevent defects/rock pockets.


Der RONDO Protect Sealing collar is positioned in the center of the concrete component.
It reliably and permanently prevents water penetration at the outer pipe wall.

Status: 26.07.2022


installation situation in floor slab

DWG allalaadimine

Lae alla PDF

installation siutation in in-situ concrete wall

DWG allalaadimine

Lae alla PDF

Võtke meiega ühendust

Vastame hea meelega teie küsimustele

Palun sisestage nimi
palun sisestage ettevõte
palun sisestage linn
Palun sisestage e-posti aadress
Palun sisestage teema
Palun sisestage sõnum

Palun täitke järgmine captcha, et vähendada rämpsposti.

Palun sisestage captcha.

Meil ei ole lubatud ühendust võtta, kui te ei nõustu meie andmekaitse avaldusega.