FB ABS 250 Deformācijas profils-250-pelēks-pastiprināts
Pastiprināts tips (V), E izmērs 210-250 mm

raksta numurs 071266V

Piezīme: Šīs lapas saturs ir tulkots automātiski un var saturēt kļūdas. Ja rodas šaubas, lūdzu, skatiet angļu vai vācu valodas versiju vai jautājiet mūsu komandai.

Svarīgākā informācija īsumā

raksta numurs:
071266V
rakstu grupa:
218 - Fugenblech (FB) Abschalelement (S+V)
GTIN:
4251689509292
muitas tarifa numurs:
72119080
iepakošanas vienība:
dators
pārdošanas daudzums vienība:
1 Stk
svars uz:
dators = 5.8 kg

© Mastertec GmbH & Co.KG

The stopend panel joint sheet metal ABS is positioned between the lower and upper reinforcement layer (foundation – foundation area) or the outer and inner reinforcement layer (wall – wall area).
The perforated plate is fastened to the reinforcement using binding wire.
The individual elements can be pushed into one another, they must overlap by at least 7 cm and the joint must be secured with two fixing clips.
With higher constructional element thicknesses, the stopend panel joint sheet metal ABS must also be stiffened in order to be structurally load-bearing.


© Mastertec GmbH &Co. KG

Before the segment is concreted, the protective foil must be removed from the joint sheet metal.
The protective foil in the section not to be concreted remains on the joint sheet metal.
Once the shuttering for the concrete segment is complete, the segment can be concreted.
The area around the stopend panel joint sheet metal ABS must be carefully waterproofed to ensure that the joint sheet metal is fully embedded in the concrete on all sides.
Cavities behind the perforated plate must be avoided.


© Mastertec GmbH & Co. KG

In the second concrete segment, as soon as the protective foil has been removed immediately before concreting, concrete can be placed directly against the stopend panel joint sheet metal ABS.
In this case, the concrete must also be carefully waterproofed in the area of the stopend panel joint sheet metal ABS.
Shrink holes or reinforcement shadow must not form around the joint sheet metal.

For thicker components, the ABS stopend panel must be reinforced on site to make it statically load-bearing.

The back anchoring and securing the position of the elements against concrete pressure is carried out at the construction site.

The distance between the "installation dimension E" reinforcement is decisive when ordering the stopend panel joint sheet metal ABS.

Status: 23.03.2022


Sazinieties ar mums!

Mūsu komanda labprāt jums palīdzēs.

Sazinieties ar mums

Mastertec GmbH & Co. KG
Im Maintal 13
Gewerbegebiet Unterhaid
96173 Oberhaid

+49 (95 03) 50 470

info@MASTERTEC.eu

Inserire l'angebot

Saņemiet šī produkta cenu piedāvājumu

FB ABS 250 Deformācijas profils-250-pelēks-pastiprināts FB ABS 250 Deformācijas profils-250-pelēks-pastiprināts
dators
please_enter_product
Lūdzu, ievadiet vārdu
lūdzu, ievadiet uzņēmumu
please_enter_ZipCode
please_enter_country
Lūdzu, ievadiet e-pasta adresi

Lūdzu, aizpildiet šo kaptcha, lai samazinātu surogātpasta daudzumu.

Lūdzu, ievadiet captcha.

Mēs nedrīkstam sazināties, ja nepiekrītat mūsu datu konfidencialitātes paziņojumam.