MASTER-RING vedante de espaço anular Ø 250 mm
para tubos de fluidos Ø 197-202 mm

número do artigo 120216

As informações mais importantes num relance

switch_to_language DE
switch_to_language GB
switch_to_language FR
switch_to_language NL
switch_to_language IT
switch_to_language ES
switch_to_language CZ
switch_to_language PL
switch_to_language RO
switch_to_language DK
switch_to_language SE
switch_to_language NO
switch_to_language FI
switch_to_language RS
switch_to_language RU
switch_to_language GR
switch_to_language TR

Ir para o Youtube

iniciar a animação
número do artigo:
120216
grupo de artigos:
440 - RRD
GTIN:
4251689528330
número da pauta aduaneira:
84842000
unidade de embalagem:
pc
unidade de quantidade de vendas:
1 Stk
peso por:
pc = 2.1 kg
material:

Elemento de vedação: borracha EPDM amiga do ambiente
Largura de vedação: 40 mm

Placas de pressão, parafusos, porcas: V2A

cor:
Elemento de borracha: preto
Placas de impressão: prateadas
Nozes:

M8

Largura entre faces:

13 mm

binário máximo:

10 Nm (tubos de meios dimensionalmente estáveis)

âmbito de aplicação térmica:
ca. -30° C a 120° C
estanquidade à pressão da água:
até 3,0 bar (sem dispositivo de segurança posicional)
até 5,0 bar (com bloqueio de posição, no local)
armazenamento:
Conservar num local seco e afastado da luz solar direta
eliminação:
Pode ser eliminado em locais de eliminação de resíduos domésticos em conformidade com os regulamentos locais de eliminação de resíduos

Supply takes place completely ready to be installed.
The MASTER-RING gasket insert consists of two pressure plates, a rubber part and the appropriate screws and nuts.
The pressure plates, the screws and the nuts are made of V2A stainless steel.


Before installation the MASTER-RING gasket insert, the inside of the core drill hole and the outside of the gas, water, sewage pipes as well as the cables have to be cleaned.


When installing a MASTER-RING gasket insert in a core drill hole the inside of the core drill hole has to be preserved with an epoxy resin ( PROTECT EP resin).
The preservation serves to obtain a smooth surface and secondly as protection of the cut reinforcement steels against corrosion.


Insert the MASTER-RING gasket insert into the lining pipe or the perserved core drill hole and push the pipe/cable through.
The MASTER-RING gasket insert must be installed as close as possible to the outside of the wall ( earth-side, water-side).
Take care that the nuts can be controlled and retightened later.
The nuts have to be placed on the air-side.


Tighten the screws crosswise through one turn.
Repeat this process until all screws are tightened to the specified max. torque.
This procedure guarantees uniform pressing out of the rubber against the inside of the lining pipe / core drill hole.
Check the torque after 1-2 hours and retighten the screws if necessary.

Status: 23.03.2022


MASTER - RING in lining pipe precast wall

Descarregar DWG

Descarregar PDF

MASTER - RING in core drill hole precast wall

Descarregar DWG

Descarregar PDF

MASTER - RING in lining pipe in-situ concrete

Descarregar DWG

Descarregar PDF

MASTER - RING in core drill hole in-situ concrete

Descarregar DWG

Descarregar PDF

Acessórios

acessórios adequados

MC-Injekt 1264 compact (resina epóxida)

Resina epóxi para vedações de encaixe forçado. Resina epóxi para preenchimento não positivo de fissuras, juntas e cavidades em es...

Contactar-nos

Teremos todo o gosto em responder às suas perguntas

Introduzir o nome
por favor, introduza a empresa
por favor, introduza a cidade
Introduzir o e-mail
Introduzir o assunto
Por favor, introduza a mensagem

Por favor, preencha o seguinte captcha para reduzir o spam.

Introduzir captcha.

Não nos é permitido entrar em contacto se não concordar com a nossa declaração de privacidade de dados.